Routines |
| Prev: 07775 | Up: Map |
|
The address of this routine is found in the parameter table.
The operand of a GO TO ought to be a line number in the range 1-9999 but the actual test is against an upper value of 61439.
|
|||||||
| GO_TO | 07783 | CALL FIND_INT2 | Fetch the operand and transfer it to the HL register pair. | ||||
| 07786 | LD H,B | ||||||
| 07787 | LD L,C | ||||||
| 07788 | LD D,0 | Set the statement number to zero. | |||||
| 07790 | LD A,H | Give the error message 'Integer out of range' with line numbers over 61439. | |||||
| 07791 | CP 240 | ||||||
| 07793 | JR NC,REPORT_B_2 | ||||||
|
This entry point is used by the routines at NEXT, CONTINUE and RETURN to determine the line number of the next line to be handled.
|
|||||||
| GO_TO_2 | 07795 | LD (23618),HL | Enter the line number (NEWPPC) and then the statement number (NSPPC). | ||||
| 07798 | LD (IY+10),D | ||||||
| 07801 | RET | Return - to STMT_RET. | |||||
| Prev: 07775 | Up: Map |